Tyvek™ Air Cargo Covers Pharmaceutical Technical Study

Purpose:
Evaluate the performance of Tyvek™ Air Cargo Cover to protect simulated Controlled Room Temperature pharmaceutical product through a simulated route in which the product is exposed to solar radiation and both hot and cold ambient extremes.
Method:
- Test sample – Euro sized pallet protected with a low emissivity Tyvek® Air Cargo Cover
- Control sample – Euro sized pallet with no protection, current case
- Pallet configuration – 18 boxes (15” x 15” x 15”) stacked 3W x 2D x 3H
- Low-to-medium thermal mass (110 liters water, liqui-packs). Simulated product – saline-filled vials.
- Temperature probes inserted into vials.
- 7 data loggers (21 temperature probes) were installed per pallet at typical excursion spots.